Testing Procedure: Performed on a Tinius Olsen 5000 Tensile Tester. The anvil arm that pushed and pulled each part traveled at a constant rate of 2.5 inches/minute. Tests performed at room temperature. Each test value represents the average of 15 pieces. Parts are dry as molded.
Note: The stated performance values represent typical values only. They are designed as a guideline for end users and are not specification values. Values stated will vary depending on the hole diameter, panel thickness, temperature, material and application. Users should conduct their own tests under specific actual conditions to determine the suitability of the fastener for a specific application.
| Part Number | Hole Diameter | Panel Range | Panel Type | Push-In | Push-Out |
| 354-190001-00-0101 | .197" | .080-.402" | Particle Board High Density Polyethylene |
20.4 15.0 |
28.9 31.0 |
| M36-0500-03 Nylon 66 (Super Tough) |
.197" | .060-.430" | Particle Board High Density Polyethylene |
18.5 12.6 |
37.0 5.2 |
| 354-250103-00-0101 | .250" | .095 - .320" | Particle Board High Density Polyethylene |
24.6 25.0 |
35.7 29.2 |
| M39-0630-10 Nylon 66 (Med. Impact) |
.250" | .098-.472" | Particle Board High Density Polyethylene |
27.5 22.6 |
57.7 10.6 |
| M36-0700-15 Nylon 66 (Med. Impact) |
.276" | .063-1.000" | Particle Board High Density Polyethylene |
52.1 29.2 |
158.4 17.2 |
| 354-280307-00-0101 | .281" | .050-.900" | Particle Board High Density Polyethylene |
72.6 37.3 |
175.1 31.7 |